ZeroFlush Cartridge Replacement Guide: When and How to Replace for Maximum Efficiency

If you’ve recently installed a ZeroFlush urinal in your business or commercial building, you’ve probably heard about the simple maintenance routine, but you may be wondering how and when to replace your ZeroFlush cartridge. To maintain proper drainage and odor control, you will need to replace your cartridges regularly. Fortunately, the process is simple and will not require a licensed plumber.

Why Cartridge Replacement Matters

While the biggest difference between traditional and waterless urinals is the absence of a flushing mechanism, the other factor that differentiates the two is the waterless urinal’s unique drainage system. Each drain is fitted with a cartridge and seal that not only removes waste from the bowl but also reduces blockages and keeps foul odors at bay.

Inside the cartridge, there’s a sealant containing an oil-based liquid that is less dense than urine. When urine passes through the sealant, the oil-based liquid helps to displace the urine, which then enters the airtight drainpipe. Over time, the liquid inside the cartridge will begin to dissipate. When this happens, the waterless urinal will experience slower drainage. If the cartridge is not replaced, sediment could begin to settle within the cartridge, leading to backups and unpleasant odors.

How Often to Replace ZeroFlush Cartridges

ZeroFlush recommends replacing the cartridge after approximately 15,000 uses, which typically equates to about six months, though this can vary based on restroom traffic volume. To avoid slow drainage or foul odors, consider creating a tracking system to ensure each cartridge is swapped out regularly. That being said, several factors could determine the lifespan of a waterless urinal’s cartridge. For example, urinals located in high-traffic areas like stadiums or hospitals will likely need more frequent replacement than those in less busy buildings or private residences. Improper cleaning procedures can also diminish the lifespan of a cartridge. When large amounts of water are used to wash the basin of the urinal, the liquid inside the sealant will dissipate more quickly.

Because manufacturer recommendations differ from product to product, it’s also important to refer to the information provided with your cartridges to determine the best time to replace them. However, if you begin to experience slow drainage, foul odors, or discoloration around the drain, these are clear indications that the cartridge should be changed, regardless of when it was last replaced.

Step-by-Step Guide to Replacing a ZeroFlush Cartridge

The process to replace a ZeroFlush cartridge is simple and does not require assistance from a licensed plumber or handyman. To get started, you’ll need:

  • New, unused ZeroFlush cartridge
  • The key that comes with the cartridge
  • Rubber gloves
  • Plastic bag for disposal
  • Soft bristle brush
  • Soapy water
  • Soft cloth
  • Disinfecting spray

Once your materials are collected, you can begin the simple process of replacing the cartridge.

Step 1

First, you will need to remove the existing cartridge. Insert the key to unlock the cartridge from the drain outlet.

Step 2

With gloves on, lift the old cartridge and tilt it slightly to drain urine and sealant that may have pooled near the top of the cartridge. Place the used cartridge in a plastic bag to dispose of it.

Step 3

Before the new cartridge is inserted, clean the opening to the drain outlet. Using a soft bristle brush, gently scrub the area around and inside the drain opening. Then flush the area with soapy water and wipe dry with a soft cloth.

Step 4

Install the new cartridge securely in the drain pipe and use the key to lock it into place.

Step 5

Lastly, refill the sealant inside the cartridge. Once it has drained into the cartridge, spray a disinfectant around the cartridge to remove traces of microbial pathogens.

Best Practices for Cartridge Maintenance

Fortunately, the design of the waterless urinal drastically reduces the likelihood of costly and time-consuming repairs, like replacing a flusher or unclogging a drain. All that is needed to keep a ZeroFlush urinal working properly is basic cleaning and regular cartridge replacement.

Follow manufacturer guidelines for replacement, but be sure to inspect the cartridge frequently, as well. If you notice slow drainage or foul odors coming from the urinal, cartridge replacement is likely needed. Consider keeping detailed inspection records to notice patterns and anticipate when each cartridge should be replaced, and follow the manufacturer’s instructions to properly swap out an old cartridge when needed.

Where to Buy Replacement Cartridges

Because a well-functioning cartridge is an essential part of a waterless urinal, it’s important to choose your cartridge wisely. While you may find a generic cartridge online that claims to be universal, it’s probably not designed for your specific urinal. Purchasing one of these universal cartridges could lead to a seal that is not airtight, inferior drainage abilities, or a much shorter lifespan of the cartridge.

Instead, consider purchasing a ZeroFlush cartridge from an authorized dealer, like AquaPro Solutions. The AquaPro Solutions website has everything you need to install and service your ZeroFlush urinal, along with experienced customer support. You can also order in bulk to ensure that your maintenance team is always ready to replace a cartridge when needed.

Replacing ZeroFlush Cartridges for Maximum Efficiency

Compared to traditional flush urinals, a ZeroFlush urinal is easier to install and even easier to maintain. To reduce foul odors and slow drainage, simply replace your urinal’s cartridge every three to six months—or after roughly 15,000 uses—to ensure quality and customer care. Purchase your ZeroFlush cartridges from a trusted distributor, like Aqua Pro Solutions. They’ll assist you with every step of the process, from installing to maintaining your ZeroFlush urinal.